Skip to main content

Products

LCB or LMU – Light Control Board

AUD $320.00AUD $1,600.00

or 4 interest-free payments with
Totale Prodotto: 320

Description

LCB or LMU – Light Control Board

All LCB are a safe, easy and simple way to manage all your light and fans in your grow room.  All LCB units are built using a hard metal enclosure with Australian approved parts and come in a variety of sizes and options.

All LCB units are hard wired and will require a qualified electrician to install.

All Boards are Made in Australia with Australian Safety Approved parts.

However, there is a 4 Outlet and 6 Outlet Plug N Play version that can be plugged straight into a power point.

Email us for 3 Phase Power boards

 

Outlets: How many plugs are on the board that are run through the timer

Live Outlets: How many plugs are available that operate 24/7 and don’t require the timer (Ideal for when separate timers are required)

A: The number of Amps that the board can handle

W: The number of watts the board can handle

T/D: Time Delay

1PH: Single phase power

 

 Available Sizes

4 Outlets 3000W, 1PH, 1 x 15A Lead (Plug N Play)

To control up to 3000W on 4 sockets with one timer

  • 10A Lead & 2m Plug
  • 15A Main Circuit Breaker
  • Led indicator for socket on/off indication

 

6 Outlets 7200W, 40A, 1PH

To control up to 7200W on 6 sockets with one timer

  • Led indicator for socket on/off indication
  • High quality reliable timer
  • 40A Main Circuit Breaker & 16A Sub Breakers
  • Separate timer lead (for reset control)

 

6 Outlets + 2 Live Outlets 8000W, 50A, 1PH

To control up to 8000W on 6 sockets with one timer and ability to connect fans, pumps etc to 2 live sockets

  • 2 x 6 mm Hard Wired Cable
  • 40A Main Circuit Breaker & 16A Sub Breakers
  • 10A Breaker for two live sockets
  • Separate timer lead (for reset control)

 

6 Outlets 6000W, 40A, 1PH, 2 x 15A Lead (Plug N Play)

To control up to 6000W on 6 sockets with one timer and ability to connect fans, pumps etc to live sockets

  • 2 x 6sqmm Hard Wired Cable
  • 2 x 15A Main Circuit Breaker
  • Separate timer lead (for reset control)

 

8 Outlets 8000W, 50A, 1PH

To control up to 8000W on 8 sockets with one timer 2 x 10 mm Hard Wired Cable

  • 50A Main Circuit Breaker & 16A Sub Breakers
  • Separate timer lead (for reset control)

 

8 Outlets + 2 Live Outlets, 8000W, 63A, 1PH

To control up to 8000W on 8 sockets with one timer and ability to connect fans, pumps etc to 2 live sockets

  • 2 x 10 mm Hard Wired Cable
  • 63A Main Circuit Breaker & 16A Sub Breakers
  • 16A Breaker for two live sockets
  • Separate timer lead (for reset control)

 

12 Outlets + 4 Live Outlets, 12000W, 80A, 1PH

To control 12000W on 12 sockets with one timer (real time clock for ease of setting) and ability to connect fans, pumps etc to 4 live sockets

  • 2 x 16 mm Hard Wired Cable
  • 80A Main Circuit Breaker & 16A Sub Breakers
  • 16A Breaker for four live sockets
  • Separate timer lead (for reset control)

 

12 Outlets + 4 Live Outlets, 12000W, 2 Timers, 80A, 1PH

To control up to 2 lots of 6000W on 6 sockets, total 12000W (6000W on one timer and 6000W on the second timer) and ability to connect fans, pumps etc to 4 live sockets

  • 2 x 16 mm Hard Wired Cable
  • 80A Main Circuit Breaker & 16A Sub Breakers
  • 16A Breaker for four live sockets
  • Two timers for a day or night time setting
  • Separate timer lead (for reset control)

 

12 Outlets + 4 Live Outlets, 1 T/D, 80A, 1PH

To control 12000W on 12 sockets with one timer.  Time Delay: Timer starts first set of six sockets, then a three-minute time delay, followed by the second set of six sockets.  There are 4 Live sockets for fans, pumps etc.

  • 2 x 16 mm Hard Wired Cable
  • 80A Main Circuit Breaker & 16A Sub Breakers
  • 16A Breaker for four live sockets
  • Time Delay between 1st and 2nd set of sockets
  • Separate timer lead (for reset control)
  • Mounting hooks provided

 

16 Outlets + 4 Live Outlets, 1 T/D, 80A, 1PH

To control lights on 16 sockets with one timer.  Time Delay: Timer starts first set of eight sockets, then a three-minute time delay, followed by the second set of eight sockets.  There are 4 Live sockets for fans, pumps etc.

  • 2 x 16 mm Hard Wired Cable
  • 80A Main Circuit Breaker & 25A Sub Breakers
  • 16A Breaker for four live sockets
  • Time Delay between 1st and 2nd set of sockets
  • Separate timer lead (for reset control)
  • Mounting hooks provided

 

24 Outlets 12 on/12 off or 24 on, 4 Live Outlets, 100A, 1PH

To control lights on two sets of 12 sockets with one timer (12 on and 12 off). There are 4 Live sockets for fans, pumps etc. or you can switch all 24 sockets on to run with one timer

  • 2 x 16 mm Hard Wired Cable
  • 100A Main Circuit Breaker & 25A Sub Breakers
  • 16A Breaker for four live sockets
  • Separate timer lead (for reset control)
  • Two sets of 12 sockets
  • Mounting hooks provided

 

24 Outlets 12 on/12 off or 24 on, 2 T/D, 4 Live Outlets, 100A, 1PH

To control lights on two sets of 12 sockets with one timer (12 on and 12 off). Time Delay: Timer starts first set of twelve sockets, then a three-minute time delay, followed by the second set of twelve sockets. There are 4 Live sockets for fans, pumps etc. or you can switch all 24 sockets on to run with one timer

  • 2 x 16 mm Hard Wired Cable
  • 100A Main Circuit Breaker & 25A Sub Breakers
  • 16A Breaker for four live sockets
  • Separate timer lead (for reset control)
  • Two sets of 12 sockets
  • 1 x 12 T/D for every 12 sockets
  • Mounting hooks provided

 

48 Outlets 24 on/24 off, 6 Live Outlets, 100A, 1PH

To control lights on two sets of 24 sockets with one timer (24 on and 24 off). There are 6 Live sockets for fans, pumps etc.

  • 2 x 16 mm Hard Wired Cable
  • 100A Main Circuit Breaker & 25A Sub Breakers
  • 16A Breaker for six live sockets
  • Separate timer lead (for reset control)
  • Two sets of 24 sockets
  • Mounting hooks provided

 

48 Outlets 24 on/24 off, 2 T/D, 6 Live Outlets, 100A, 1PH

To control lights on two sets of 24 sockets with one timer (24 on and 24 off). Time Delay: Timer starts first set of twelve sockets, then a three-minute time delay, followed by the second set of twelve sockets. There are 6 Live sockets for fans, pumps etc.

  • 2 x 16 mm Hard Wired Cable
  • 100A Main Circuit Breaker & 25A Sub Breakers
  • 16A Breaker for six live sockets
  • Separate timer lead (for reset control)
  • Two sets of 24 sockets
  • 1 x 12 T/D for every 12 sockets
  • Mounting hooks provided

Reviews

There are no reviews yet.

Be the first to review “LCB or LMU – Light Control Board”

Your email address will not be published. Required fields are marked *